Operation CHARM: Car repair manuals for everyone.

Secondary Air Injection Solenoid Valve, Checking







Secondary Air Injection Solenoid Valve, Checking

Special tools, testers and auxiliary items required

• Multimeter.

• Wiring diagram.

Test requirements

• The Secondary Air Injection (AIR) Solenoid Valve (-N112-) fuse OK.

• The Engine Control Module (ECM) Power Supply Relay (J271) fuse OK.

• Battery voltage at least 12.5 V.

• All electrical consumers switched off (radiator fan must NOT run during test).

• A/C switched off.

• The ignition switched OFF.

Test procedure

- Perform a preliminary check to verify the customers complaint. Refer to => [ Preliminary Check ] Preliminary Check.

Start diagnosis

• Voltage is supplied to the Secondary Air Injection (AIR) Solenoid Valve (N112) from fuse 24 in Fuse Box B.

Procedure

- Disconnect the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector - 1 -.





Checking internal resistance

- Using a multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) terminals 1 to 2 for resistance.

Specified value: 3.5-8.5 ohms (at approx. 20° C)

If the specified value was Not obtained:

- Replace the Secondary Air Injection (AIR) Solenoid Valve (N112). Refer to the Repair Information.

If the specified value was obtained:

Checking voltage supply

Switch the ignition ON.

- Using a multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical connector terminal 1 to Ground for voltage.

Specified value: Battery voltage.

Switch the ignition OFF.

If the specified value was Not obtained:

- Check the wiring from the Secondary Air Injection (AIR) Solenoid Valve (N112) terminal 1 to fuse 20 in Fuse Panel B for a short circuit to Ground, or an open circuit.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the wiring connection and replace fuse 20 in Fuse Panel B if blown.

If the specified value was obtained:

Checking wiring

- Remove the Engine Control Module (ECM) (J623). Refer to the Repair Information.

- Using a multimeter, check the Secondary Air Injection (AIR) Solenoid Valve (N112) electrical harness connector to the Engine Control Module (ECM) (J623) electrical harness connector T60 for an open circuit.










Specified value: 1.5 ohms Max.

If the specified value was Not obtained:

- Check the wiring for an open, high resistance or short to ground.

- Check the electrical harness connector for damage, corrosion, loose or broken terminals.

- If necessary, repair the faulty wiring connection.

If no malfunction is detected in the wiring and the voltage supply was OK:

- Replace the Engine Control Module (ECM) (J623). Refer to the Repair Information.

Final procedures

After the repair work, the following work steps must be performed in the following sequence:

1. Check the DTC memory. Refer to => [ Diagnostic Mode 03 - Read DTC Memory ] Diagnostic Modes 01 - 0A.

2. If necessary, erase the DTC memory. Refer to => [ Diagnostic Mode 04 - Erase DTC Memory ] Diagnostic Modes 01 - 0A.

3. If the DTC memory was erased, generate readiness code. Refer to => [ Readiness Code ] Monitors, Trips, Drive Cycles and Readiness Codes.