Installation
HEATING / AIR CONDITIONING: AIR CONDITIONING PRESSURE SENSOR: INSTALLATION
1. INSTALL AIR CONDITIONER PRESSURE SENSOR
(a) Apply a sufficient amount of compressor oil to a new air conditioner pressure sensor.
Compressor oil:
ND-OIL 11 or equivalent
NOTICE:
* Keep the O-ring and O-ring fitting surfaces clean from dirt or any foreign matter.
* Do not use any compressor oil other than ND-OIL 11 or equivalent. If any compressor oil other than ND-OIL 11 or equivalent is used, compressor motor insulation performance may decrease, resulting in a leakage of electric power.
(b) Install the new air conditioner pressure sensor.
Torque : 11 Nm (110 kgf-cm, 8 ft-lbf)
NOTICE:
* Do not deform the piping.
* Make sure to confirm that the piping does not disengage from the plastic clamp.
(c) Connect the connector.
2. CONNECT CABLE TO AUXILIARY BATTERY NEGATIVE TERMINAL
NOTICE:
When disconnecting the cable, some systems need to be initialized after the cable is reconnected Repair Instruction - Initialization.
3. INSTALL DECK FLOOR BOX RH Installation
4. INSTALL REAR DECK FLOOR BOX Installation
5. INSTALL NO. 2 DECK BOARD Installation
6. INSTALL NO. 1 DECK BOARD Installation
7. INSTALL DECK BOARD ASSEMBLY Installation
8. CHARGE AIR CONDITIONING SYSTEM WITH REFRIGERANT Service and Repair
9. WARM UP COMPRESSOR Service and Repair
10. INSPECT FOR REFRIGERANT LEAK Service and Repair