Initial Inspection and Diagnostic Overview
P4 POWER WINDOW CONTROL SW LH2-GROUND : Always continuity
5-2 : Closed with the power window control SW at AUTO DOWN position
4-2 : Closed with the power window control SW at DOWN position
6-2 : Closed with the power window control SW at UP position
P5 POWER WINDOW CONTROL SW RH
4-1 : Closed with the power window control SW at DOWN position
4-3 : Closed with the power window control SW at UP position
W1 WINDOW LOCK SW
7-10 : Open with the window lock SW at LOCK position