Leak Detection Solenoid: Testing and Inspection
VSV FOR CANISTER CLOSED VALVE (CCV)INSPECTION
1. REMOVE VSV
a. Disconnect the air hose from the VSV.
b. Disconnect the VSV connector for canister closed valve.
c. Remove the screw and VSV from air cleaner cap.
2. INSPECT VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between terminals.
Resistance: 25 - 30 Ohms at 20° C (68° F)
If there is no continuity, replace the VSV.
3. INSPECT VSV FOR GROUND
Check that there is no continuity between each terminal and the body.
If there is continuity, replace the VSV.
4. INSPECT VSV OPERATION
a. Check that air flows from port B to A.
b. Apply battery positive voltage across the terminals.
c. Check that air flows with difficulty from port B to A.
If operation is not as specified, replace the VSV.
5. REINSTALL VSV
a. Install the VSV with the screw to the air cleaner cap.
b. Connect the VSV connector for canister closed valve.
c. Connect the air hose to the VSV.