Operation CHARM: Car repair manuals for everyone.

EGR Control Solenoid: Testing and Inspection

1. REMOVE V-BANK COVER, HIGH-TENSION CORD COVER AND EMISSION CONTROL VALVE SET
2. REMOVE [1][2][3][4]VSV

a. Disconnect the 3 vacuum hoses from the VSV.
b. Remove the screw and [1][2][3][4]VSV.





3. INSPECT [1][2][3][4]VSV FOR OPEN CIRCUIT
Using an ohmmeter, check that there is continuity between the terminals.

Resistance: 27-33 Ohms at 20° C (68° F) If there is no continuity, replace the [1][2][3][4]VSV.





4. INSPECT [1][2][3][4]VSV FOR GROUND
Using an ohmmeter, check that there is no continuity between each terminal and the body.
If there is continuity, replace the [1][2][3][4]VSV.

5. INSPECT [1][2][3][4]VSV OPERATION





a. Check that air flows from port E to port G.





b. Apply battery positive voltage across the terminals.
c. Check that air flows from port E to port F.
If operation is not as specified, replace the [1][2][3][4]VSV.

6. REINSTALL [1][2][3][4]VSV
a. Install the VSV with the screw.
b. Connect the 3 vacuum hoses to the [1][2][3][4]VSV.

7. REINSTALL EMISSION CONTROL VALVE SET
8. REINSTALL HIGH-TENSION CORD COVER
9. REINSTALL V-BANK COVER