Continuity and Resistance Check
Continuity And Resistance Check:
a. Disconnect the battery terminal or wire so there is no voltage between the check points.
b. Contact the two leads of an ohmmeter to each of the check points.
- If the circuit has diodes, reverse the two leads and check again.
- When contacting the negative lead to the diode positive side and the positive lead to the negative side, there should be continuity.
- When contacting the two leads in reverse, there should be no continuity.
Continuity And Resistance Check:
c. Use a Volt/Ohm meter with high impedance (10 KOhms/Volt minimum) for troubleshooting of the electrical circuit.