Federal Models
VACUUM SWITCHING VALVE (VSV) FOR EGR INSPECTION1. REMOVE VSV.
Vacuum Switching Valve For The EGR Valve:
a. Disconnect VSV electrical connector.
b. Remove hose connections from VSV.
c. Unbolt and remove valve.
2. INSPECT FOR OPEN CIRCUIT.
- Using an ohmmeter, check that there is continuity between the terminals.
Resistance at 20°C (68°F): 33 - 39 Ohms.
- If there is no continuity, replace the VSV.
3. INSPECT FOR SHORT CIRCUIT.
- Check for continuity between each VSV terminal and the valve body.
- Replace VSV is continuity is found.
4. INSPECT VSV OPERATION.
a. Blow through port E, air should not flow from port G.
b. Apply battery voltage across valve terminals.
c. Blow through port E, air should flow from the filter.
- If operation is not as specified, replace the VSV.
5. REINSTALL VSV.