Idle Up Control Valve: Testing and Inspection
A/C IDLE-UP VALVE INSPECTION1. Remove idle-up valve.
2. Inspect Idle-Up Valve for open circuit.
- Using an ohmmeter, check that there is continuity between the terminals.
Resistance: 30 - 34 Ohms at 20°C (68°F)
^ If there is no continuity, replace the Idle-Up Valve.
3. Inspect idle-up valve for ground.
- Using an ohmmeter, check that there is no continuity between each terminal and the body.
^ If there is continuity, replace the Idle-Up Valve.
4. Inspect idle-up valve operation.
- Check that the air does not flow from port E to port F.
- Apply battery voltage across the terminals.
- Check that the air flows from port E to port F.
^ If operation is not as specified, replace the idle-up valve.
4. Reinstall idle-up valve.