No Blower Speed Control

Fig. 6 Installing Check Connector Into Amplifier.:




Fig. 7 Checking Power Servo Stem Position.:





NOTE: Refer to WIRING DIAGRAMS for correct terminal identification.

1. Turn ignition switch On, and check blower operation by selecting each position.
a. If blower motor operates at Lo, Med and Hi, proceed to step 4.
b. If blower motor operates at Hi only, proceed to step 2.
1. Check voltage at terminal 6 of blower motor relay. If there is voltage, proceed to step 3. If there is no voltage, repair open circuit in wire from blower motor to blower motor resistor.
2. Check continuity between blower resistor and ground at terminal 3 with blower switch in Med. position and terminal 1 with blower switch in the Lo position. If there is continuity, check and replace switch, or repair open circuit in blower switch wire.
3. Start engine and allow it to reach normal operating temperature.
4. Place blower switch in "AUTO" position.
5. Disconnect "check" connector from its normal connection, and connect it to the "check" connector of the amplifier, Fig. 6, then check that power servo stem moves smoothly by sliding the temperature control lever. If servo stem does not move, Fig. 7, proceed to step 7. If servo stem moves, check in-car sensor, ambient sensor and open circuit in sensor wire. Replace of repair as necessary.
6. If air flow control lever is placed at HEAT, check continuity between terminal 2 of A/C cut off relay and ground. If there is continuity, proceed to step 8. If there is no continuity, check warm up relay at 85 deg. F, coolant temperature switch at 85 deg. F, blower switch and for an open circuit in blower switch wire. Replace and repair as necessary.
7. Check continuity between terminal 6 of power servo and ground. If there is no continuity, check warm up relay and coolant temperature switch at 122 deg. F., the blower motor switch and the blower motor switch wire for an open circuit. Replace and repair as necessary. If there is continuity, refer to "Improper Temperature Control".