BARO / MAP Sensor Switching Valve: Description and Operation
Vacuum/Atmospheric Pressure Sensor and VLC Solenoid:
PURPOSE
Vacuum line control (VLC) solenoid valve switches the source line for the vacuum/pressure sensor.
LOCATION
Attatched to a bracket on the R.F. fender apron.
OPERATION
With no voltage to the solenoid, the sensor monitors intake manifold vacuum. When the solenoid is energized, the sensor measures atmospheric pressure.