D) Cold Start Inter Lock (Test Lamp/Ohmmeter)
D) COLD START INTER LOCK (Test Lamp/Ohmmeter)The cold start interlock has the task of regulating the flap program to DEF flap position in positions ECO, AUTO and BI, without blower speed 4, when the engine is cold (coolant temperature below 40 °C).
Opening the circulating air flap (fresh air closed) prevents cold fresh air from entering the passenger compartment. Cold start interlock is switched off when reaching a coolant temperature of 40 °C and flaps are regulated to the pertinent program switch position (ECO, AUTO, BI).
Testing
1. Cold Engine
a) Connect test lamp on solenoid valve bar and B+.
b) Set program switch to ECO, AUTO or BI. Turn on ignition.
c) Set temperature control lever to 30 °C. Operating motor should run up fully (disconnect plug 4, if the motor does not run up).
Test lamp must not come on.
(coolant temp. below 40 °C = sensor resistance greater than 285 ohms)
d) Pull term. g wire (large plug connector) off of coolant temperature sensor in engine compartment.
Test lamp must come on.
e) Connect plug term. G again (test lamp goes out) and operate the engine.
Test lamp must come on after brief time.
(coolant temp. above 40 °C sensor resistance less then 285 ohms)
2. Warm Engine
a) Connect test lamp on solenoid valve bar and B+.
b) Set program switch to ECO, AUTO or BI. Turn on ignition.
c) Set temperature control lever to 30 °C. Operating motor must run up fully (disconnect plug 4, if motor does not run up).
Test lamp must come on.
(coolant temp. above 40 °C = sensor resistance less than 285 ohms).
d) Pull off term. G wire (large plug connector) on coolant temperature sensor in engine compartment.
Test lamp must remain on.