Air Outlet Duct Replacement - Extended Console
AIR OUTLET DUCT REPLACEMENT - EXTENDED CONSOLERemoval Procedure
1. Remove the floor console.
2. Remove the center console end panel.
3. Remove the screw from the rear duct (4).
4. Remove the rear duct from the console.
5. Remove the left console trim panel.
6. Remove the screw from the front duct (5).
7. Remove the front duct from the HVAC module.
Installation Procedure
1. Install the front duct (5) to the HVAC module.
NOTICE: Refer to Fastener Notice in Service Precautions.
2. Secure the front duct with the screw.
Tighten
Tighten the screw to 2 N.m (18 Ib in).
3. Install the left console trim panel.
4. Install the rear duct (4) to the console. Secure with the screw.
Tighten
Tighten the screw to 2 N.m (18 Ib in).
5. Install the center console end panel.
6. Install the floor console.