Canister Purge Control Valve: Testing and Inspection
EVAP Canister Purge Valve InspectionTools Required
J 39200 Digital Multimeter
1. Disconnect the EVAP canister purge valve electrical connector.
2. Measure the resistance between the electrical terminals of the EVAP canister purge valve (2) with the DMM (1). The resistance should be 28 to 39 ohms at 20°C (68°F).
3. Replace the EVAP canister purge valve if the resistance is not 28 to 39 ohms at 20°C (68°F). Proceed to step 4 if the resistance is within the specification. Refer to EVAP Canister Purge Valve Replacement.
Figure 2:
4. Disconnect the EVAP canister purge valve vacuum hose (3) from the intake manifold.
5. Disconnect the EVAP canister purge valve vacuum hose (2) from EVAP canister.
6. Blow air into the EVAP canister purge valve vacuum hose (2) that was disconnected from the EVAP canister. Air should not pass through the EVAP canister purge valve (1) and exit from the intake manifold hose (3).
7. Connect 12 volts DC to the EVAP canister purge valve electrical terminals.
8. Blow air into the EVAP canister purge valve vacuum hose that was disconnected from the EVAP canister. Air should pass through the EVAP canister purge valve and exit from the intake manifold hose.
9. Replace the EVAP canister purge valve if the EVAP canister purge valve failed this inspection. Refer to EVAP Canister Purge Valve Replacement.
10. Connect the EVAP canister purge valve vacuum hoses.
11. Connect the EVAP canister purge valve electrical connector