Canister Purge Control Valve: Service and Repair
Removal Procedure1. Disconnect the negative (-) battery cable.
2. Disconnect the Evaporative Emission (EVAP) Canister Purge Valve electrical connection.
3. Disconnect the two vacuum hoses from the EVAP Canister Purge Valve.
4. Remove the two screws from the EVAP Canister Purge Valve to the intake manifold.
5. Remove the EVAP Canister Purge Valve from the intake manifold.
Installation Procedure
1. Install the EVAP Canister Purge Valve to the intake manifold and secure with two screws.
2. Connect the two vacuum hoses to the EVAP Canister Purge Valve.
3. Connect the EVAP Canister Purge Valve electrical connector.
4. Connect the negative (-) battery cable. Tighten the negative (-) battery cable-to-negative (-) battery terminal retainer to 15 Nm (11 lb. ft.).