DTC 28 - P0705
Name of Code:
P-0705(28) - Check Shifter Signal When monitored: Continuously with the key on. Set condition: 3 occurrences in one key start of an invalid PRNDL code which lasts for more than 0.1 second.
Theory of Operation: The T1, T3, T41, and T42 sense circuits communicate the shift lever position to the TCM. Each circuit is terminated at the transmission with a switch. Each switch can be either open or closed, depending on the shift lever position. The TCM can decode this information and determine the shift lever position. Each shift lever position has a certain combination of switches which will be open and closed, this is called a PRNDL code. There are 4 switches, therefore: there are many possible combinations of open and closed switches (codes). However, there are only 9 valid codes (8 for Autostick), one for each gear position and three recognized between gear codes. The remainder of the codes should never occur, these are called invalid codes. The following chart shows the normal switch states for each shift lever position.
Transmission Effects and Possible Causes:
Scenario 1) - All PRNDL lights stay illuminated indefinitely in Park following a key start.
- Wrong Part Number TCM for application
- TRS connector not plugged in
- T1, T3, T41, or T42 circuits are either open, shorted to ground, or shorted to 12 volts.
- bus failure (Open or shorted resulting in no communication to BCM or Cluster)
- TRS
- TCM
- BCM
Scenario 2) - "P" is indicated following a key start but all PRNDL lights illuminate in "N" following a shift from "R" to "N". If PRNDL lights illuminate in "N" and shifter is moved directly into "319 or 49129 position without pausing in "OD", then the "OD" position shift schedule and electronic display will indicate "OD" until the shifter is shifted into the "OD" position and held for at least 3 seconds.
- Worn Manual Lever (Rooster Comb). Check for heavy wearing by TRS switch contacts
- Intermittent T1, T3, T41 or T42 circuits. Check for corrosion, terminal push-outs or spread terminals at 60-way and/or TRS switch 10-way connector
- TRS
- TCM
- BCM
Scenario 3) - If the invalid code happened while operating in the "3" or "D position, then the "3" or "D' shift schedule and electronic display will be frozen (regardless of whether "OD", "T' or "D is selected) until the shifter is moved to the "N" position (all PRNDL light will illuminate) and then back to the "OD" position and held there for at least 3 seconds in order to resume the normal "OD" shift schedule and electronic display.
- Intermittent T1, T3, T41 or T42 circuits. Check for corrosion, terminal push-outs or spread terminals at 60-way and/or TRS, MVLPS, P/N, or PRNDL switch 10-way connector
- TRS
- TCM
- BCM
These same symptoms may occur without the fault code P-0705(28) getting set. It is possible that the invalid code that was sensed by the TCM only occurred once or twice during the given ignition key start and/or did not last for longer than 0.1 second.