Operation CHARM: Car repair manuals for everyone.

Initial Inspection and Diagnostic Overview

1. Check scan tool operation on a known good vehicle to make sure tool is operating properly.
2. Check condition of IPC/HVAC BATT Fuse by visual inspection.
3. Verify that Grounds G102 and G201 are clean and tight.
4. Check for proper connection of scan tool to the Data Link Connector (DLC).
5. The following diagnostics assume that a communications failure is initially found during testing with the scan tool as per the appropriate service manual sections (Driveability and Emissions, Antilock Brakes, Supplemental Inflatable Restraints, Computer System Diagnosis).
^ Check for a broken (or partially broken) wire inside the insulation which could cause system malfunction but prove GOOD in a continuity/voltage check with a system disconnected. These circuits may be intermittent or resistive when loaded, and if possible, should be checked by monitoring for a voltage drop with the system operational (under load).
^ Check for proper installation of aftermarket electronic equipment which may affect the integrity of other systems (refer to General Troubleshooting Procedures). Diagnostic Aids