Operation CHARM: Car repair manuals for everyone.

Dynamic Line Pressure Testing

The vehicle diagnostic overrides control the transmission pressure control solenoid:
- In Park and neutral with the vehicle stopped at idle
- In a dynamic mode during road testing

Under dynamic test conditions, you can override the solenoid's pressure signal in order to increase pressure from the normal PCM commanded pressure. During road test conditions, you can command high line pressures in order to verify a response from the line pressure system.
To verify the line pressure response in the dynamic mode, access MISC. TESTS. Select A/T OUTPUTS-PC SOLENOID and drive the vehicle
under normal road test conditions.

While driving the vehicle, depress the Up Arrow in order to gradually increase the transmission fluid pressure. As the transmission fluid pressure increases, transmission upshifts should become progressively harsher. This occurs because in this test mode line pressures are commanded which are higher than required.

If the pressure readings differ greatly from the Line Pressure specification, refer to Symptom Tables.