Input Test: II08 (Fuel Gage Switch) With Digital Cluster Only
Fuel Gage Switch Wiring:
PROPER II08 DIAGNOSTIC DISPLAYS
- HI is displayed with Fuel Gage Switch released.
- LO is displayed with Fuel Gage Switch depressed.
TESTS FOR IMPROPER DISPLAYS
II08 displays HI with Fuel Gage Switch depressed.
1. Remove Left Switch Assembly. Connect a fused jumper wire between terminals B12 and B7 of Left Switch Assembly Connector.
^ If display reads HI, go to step 2.
^ If display reads LO, check connections. If connections are good, replace Left Switch Assembly.
2. Connect fused jumper wire between terminal B12 of the Left Switch Assembly Connector and ground.
^ If display reads HI, go to step 3.
^ If display reads LO, repair BLK (804) wire for an open.
3. Remove Instrument Panel Cluster (IPC). Connect an ohmmeter between Instrument Panel Cluster Connector, terminal D11 and Left Switch Assembly Connector, terminal B12.
^ If 0 ohms is measured, replace Instrument Panel Cluster (IPC) if terminal contact is OK.
^ If high resistance is measured, check/repair LT BLU (224) wire for an open.
II08 displays LO with Fuel Gage Switch released.
1. Remove Left Switch Assembly.
^ If display reads HI, replace Left Switch Assembly.
^ If display reads LO, go to step 2.
2. Check LT BLU (224) wire for a short to ground. If LT BLU (224) wire is OK, replace the Instrument Panel Cluster (IPC).