With Electronic Climate Control
OperationThe Blower Off Relay is energized when the Air Conditioning System is off. The Relay contacts open and remove Battery voltage from the Blower Resistors and the Blower Motor.
Low and Medium Speeds
When any of the operating buttons in the Heater and A/C Control Assembly are pressed, the ground is connected to the Blower Off Relay. The relay is energized and its contacts close. When the Blower Speed Control Switch is pushed to display M1, a solid state switch in the Heater and A/C Control Assembly closes to connect the BRN and TAN wires. This by-passes the first resistor and the motor speed increases. In the M2 position, two resistors are by-passed and only one remains in the circuit.
High Speed
When the Blower Speed Control Switch is in the HI position, voltage is applied to the High Speed Blower Relay. The relay closes and applies Battery voltage directly to the Blower Motor. The motor then runs at maximum speed.