Operation CHARM: Car repair manuals for everyone.

Service Limits & General Specifications

CONNECTING ROD SIDE CLEARANCE





- Measure the side clearance between connecting rod and crankshaft arm with feeler gauge.
Standard: 0.20 - 0.35 mm (0.0080 - 0.0138 in)
Limit: 0.40 mm (0.0160 in)
- If the measured value exceeds the limit, replace connecting rod, and measure again. If it still exceeds the limit, replace crankshaft also.

CONNECTING ROD BEND AND TORSION





- Check with connecting rod aligner.
Bend:
Limit: 0.15 mm (0.0059 in) per 100 mm (3.94 in) length
Torsion:
Limit: 0.30 mm (0.0120 in) per 100 mm (3.94 in) length
- If it exceeds the limit, replace connecting rod assembly.





CONNECTING ROD