Air Flow Meter/Sensor: Service and Repair
AIR CLEANER AND AIR DUCTRemoval and Installation
Exploded View EM-15:
REMOVAL
1. Remove clips, and slide air duct (inlet) frontward, disengage clips and air cleaner case.
NOTE: When removing air duct (inlet), remove front bumper and bumper fascia stay radiator core support center.
3. Disconnect PCV hose.
4. Remove air cleaner case/mass air flow sensor assembly and air duct assembly disconnecting their joints.
- Add marks as necessary for easier installation.
5. Remove mass air flow sensor from air cleaner case.
CAUTION: Handle mass air flow sensor with care.
- Do not shock it.
- Do not disassemble it.
- Do not touch its sensor.
INSPECTION AFTER REMOVAL
Inspect air duct for crack or tear.
- If anything found, replace air duct.
INSTALLATION
Note the following, and install in the reverse order of removal.
- Align marks. Attach each joint. Screw clamps firmly.
CAUTION: Keep the clearance more than 5 mm between tower bar and air duct.