Thermal Limiting Fuse: Service and Repair
THERMAL PROTECTOR REMOVAL/INSTALLATION1. Remove the A/C, compressor
2. Remove in the order as indicated below.
1. Screw
2. Clip
3. Screw
4. Clamp
5. Thermal protector
3. Install in the reverse of the removal.
Thermal protector removal note
1. After removing the thermal protector, completely remove the silicone adhering to the A/C compressor side.
Thermal protector installation note
1. Apply approximately 1 g {0.04 oz} of silicone (Shin-Etsu Silicone KE-347W or similar) to the contact surface of the thermal protector, then thoroughly install onto the A/C compressor, leaving no gaps.