Operation CHARM: Car repair manuals for everyone.

Variable Induction Control Solenoid: Testing and Inspection

VARIABLE TUMBLE CONTROL SYSTEM (VTCS) SOLENOID VALVE INSPECTION

Airflow Inspection

NOTE: Perform the following test only when directed.

1. Remove the VTCS solenoid valve.







2. Inspect for airflow between each port under the following condition.
- If as specified but the Simulation Test is failed, inspect for the following and carry out the "Circuit Open/Short Inspection". Vacuum hose improper routing, kinks or leakage.
- If not as specified, replace the VTCS solenoid valve.

Circuit Open/Short Inspection




Open circuit
- Power circuit (VTCS solenoid valve connector terminal A and main relay connector terminal D through common connector)
- GND circuit (VTCS solenoid valve connector terminal B and PCM connector terminal 2N)

Short circuit
- VTCS solenoid valve connector terminal A and main relay connector terminal D through common connector to GND