Thermo Time Switch: Service and Repair
COLD-START THERMOSWITCH
Removal / Installation
1. Disconnect the cold start thermoswitch connector.
2. Remove the cold start thermoswitch.
3. Use new packing and install in the reverse order of removal.
Tightening Torque: 30-39 Nm (22-28 ft.lb.)