Inspection
ATF THERMOSENSORInspection
1. Refer to "Replacement" for removal of the ATF thermosensor.
2. Place the ATF thermosensor in water with a thermometer as shown, and heat the water gradually.
3. Measure the resistance between the terminals of the thermosensor.
4. If not correct, replace the ATF thermosensor.
5. Refer to "Replacement" for installation of the ATF thermosensor.