Cold Start Relay: Testing and Inspection
COLD-START INJECTOR RELAY
Inspection
1. Apply battery positive voltage to terminal C and ground terminal E of the cold-start injector relay.
2. Check continuity of the relay as shown.
B+: Battery positive voltage
3. If not as specified, replace the cold-start injector relay.