Evaporative Check Valve: Testing and Inspection
Check Valves:
TWO-WAY
1. Remove valve.
2. Check operation with vacuum pump.
3. Apply approximately 1.46 inHg (37mmHg, 5 kPa) vacuum to port A. Check that air flows through valve.
4. Apply approximately 1.73 inHg (44mmHg, 6 kPa) vacuum to port B. Check that air flows through valve.
5. If not as specified, replace valve.
ONE-WAY
1. Remove valve.
2. Blow through valve from port A. Check that air flows through from port B.
3. Blow through valve from port B. Check that no air flows through from port A.
4. If not as specified, replace valve.