Air Diverter Solenoid: Testing and Inspection
SOLENOID VALVE (PORT AIR BYPASS) SYSTEM OPERATIONSolenoid Valve (Port Air Bypass) Inspection:
1. Connect Mazda SST (Engine Signal Monitor Adapter Harness), or equivalent test equipment.
2. Turn ignition "ON." Short ECU terminal 3N and verify solenoid operational sound ("click") is heard.
SOLENOID VALVE (PORT AIR BYPASS) INSPECTION
1. Unplug valve electrical connector.
2. Measure resistance across solenoid connector. If not as specified, replace valve.
RESISTANCE @ 68°F (20°C): 26.6 - 32.6 Ohms
SOLENOID VALVE (SPLIT AIR BYPASS) SYSTEM OPERATION
Solenoid Valve (Split Air Bypass) Inspection:
1. Connect Mazda SST (Engine Signal Monitor Adapter Harness), or equivalent test equipment.
2. Turn ignition "ON." Short ECU terminal 4F and verify solenoid operational sound ("click") is heard.
SOLENOID VALVE (SPLIT AIR BYPASS) INSPECTION
1. Unplug valve electrical connector.
2. Measure resistance across solenoid connector. If not as specified, replace valve.
RESISTANCE @ 68°F (20°C): 27 - 32 Ohms
SOLENOID VALVE (RELIEF 2) SYSTEM OPERATION
Solenoid Valve (Relief 2) Inspection:
1. Connect Mazda SST (Engine Signal Monitor Adapter Harness), or equivalent test equipment.
2. Turn ignition "ON." Short ECU terminal 3K and verify solenoid operational sound ("click") is heard.
SOLENOID VALVE (RELIEF 2) INSPECTION
1. Unplug valve electrical connector.
2. Measure resistance across solenoid connector. If not as specified, replace valve.
RESISTANCE @ 68°F (20°C): 27 - 32 Ohms