A/C - Poor Output
Bulletin: P91-011Section: PRODUCT
Dated: 6/25/91
Applicable to: USA, CANADA
SUBJECT:
1990/1991 AIR CONDITIONING TEMPERATURE LEVER
Complaints of low A/C output or short compressor cycling can be caused by the temperature lever ("B" on illustration) becoming disconnected from the temperature control slide (potentiometer).
WORK PROCEDURE
^ Remove HVAC knobs and face-plate.
^ Re-install plastic link on temperature lever to the control slide.
^ Install spring clip - MXC7656 - on control slide to prevent future failure.
^ Re-install face plate and knobs taking care not to pinch or trap illumination wiring.
The clip (MXC7656) has been Factory installed from VIN ...MA600918.
WARRANTY INFORMATION
Submit warranty claims as follows:
Service Type: WW
Repair Code: 7S4Z
Labor Operation: 822000 - 1.0 hr (w/wood A/C fascia)
.4 hrs (w/plastic A/C fascia - Hunter)