Procedures
Exploded View TF-45:
TRANSFER FLUID
Inspection
FLUID LEAKAGE AND FLUID LEVEL
1. Check if fluid is leaking from transfer or around it.
2. Check fluid level from filler plug mounting hole as shown in the figure.
CAUTION: Never start engine while checking fluid level.
3. Before installing filler plug, set a new gasket. Install filler plug on transfer and tighten to the specified torque. Refer to Exploded View TF-45.
CAUTION: Do not reuse gasket.