Catalytic Converter: Service and Repair
EXHAUST MANIFOLD AND THREE WAY CATALYSTRemoval and Installation
REMOVAL
1. Remove engine cover with power tool.
2. Remove air cleaner case and air duct.
3. Remove undercover with power tool.
4. Using heated oxygen sensor wrench (special service tool), remove rear heated oxygen sensors.
CAUTION: Be careful not to damage heated oxygen sensor.
5. Remove bracket between right/left catalytic converter and transmission.
6. Remove three way catalyst.
7. Using heated oxygen sensor wrench (special service tool), remove front heated oxygen sensors.
CAUTION: Be careful not to damage heated oxygen sensor.
8. Remove water pipes on both RH and LH side.
9. Remove exhaust manifold cover.
10. Loosen nuts in the reverse order of illustration to remove exhaust manifold with power tool.
CAUTION: Disregard the numerical order No. 7 and No. 8 in removal.
INSPECTION AFTER REMOVAL
Surface Distortion
^ Use a reliable straightedge and feeler gauge to check the flatness of exhaust manifold fitting surface.
Limit: 0.3 mm (0.012 inch)
INSTALLATION
^ Install in the reverse order of removal paying attention to the following.
Installation of Exhaust Manifold Gasket
^ Install in direction shown. (Follow same procedure for both banks.)
^ Locate thick side of port connecting part on right side from technician's view.
^ Locate round press in thick side of port connecting part above center level line of port.
Installation of Exhaust Manifold
^ If stud bolts were removed, install them and tighten to the torque specified below.
: 12.7 - 16.7 Nm (1.3 - 1.7 kg-m, 10 - 12 ft. lbs.)
Right Bank Bolt Torque Sequence:
Left Bank Bolt Torque Sequence:
^ Install exhaust manifold in the numerical order as shown in the figure.
^ Tighten nuts No. 1 and No. 2 in two steps. The numerical order No. 7 and No. 8 shows second step.
Installation of Heated Oxygen Sensor
CAUTION:
^ When using heated oxygen sensor wrench (KV10114400), tighten to the middle of specified torque because length of tool may induce slight indication increase. Do not tighten to the maximum specified torque.
^ Before installing a new heated oxygen sensor, clean exhaust system threads using heated oxygen sensor thread clearer tool, J-43897-18 or J-43897-12, and apply anti-seize lubricant.
^ Do not over torque the heated oxygen sensor. Doing so may cause damage to the heated oxygen sensor, resulting in the MIL coming on.