Operation CHARM: Car repair manuals for everyone.

Shift Solenoid Relay: Testing and Inspection

A/T Control Relay Check
1 Remove the A/T control relay.
2 Use jumper wires to connect A/T control relay terminal (2) to the battery (+) terminal and terminal (4) to the battery (-) terminal.
3 Check the continuity between terminal (1) and terminal (3) of the A/T control relay when the jumper wires are connected to and disconnected from the battery.






4 If there is a problem, replace the A/T control relay.