CVT Driven Pulley Pressure Control Valve Removal/Installation
CVT Driven Pulley Pressure Control Valve Removal/Installation
1. Disconnect the CVT driven pulley pressure control valve connector (A) and the inhibitor solenoid connector (B).
2. Remove the CVT driven pulley pressure control valve (C), and remove the inhibitor solenoid (D) from the CVT driven pulley pressure control valve.
3. Check that the filter (E) is in good condition, and replace it if it is clogged or damaged.
4. Remove the O-rings (F) from the inhibitor solenoid.
5. Install the O-rings on the inhibitor solenoid, then install the inhibitor solenoid on the CVT driven pulley pressure control valve.
6. Install the CVT driven pulley pressure control valve with the dowel pins (G) and the separator plate (H) on the lower valve body (I).
7. Connect the CVT driven pulley pressure control valve connector and the inhibitor solenoid connector.