Compressor Clutch Diode HVAC: Testing and Inspection
NOTE: The diodes are designed to pass current in one direction and block current in opposite direction.
1. Using an ohmmeter or continuity tester, check the diodes.
2. Connect positive probe to B terminal and negative probe to A terminal.
- There should be continuity.
3. Reverse the test probe positions and check.
- There should be no continuity.
4. Check the other diode (terminals C and D). Connect positive probe to C terminal and negative to D.
- There should be continuity.