Air Conditioning
Component Locations:
The A/C refrigerant system is a clutch cycling orifice tube type. The system components are:
- A/C compressor.
- A/C clutch assembly.
- A/C condenser core.
- A/C evaporator core.
- suction accumulator.
- connecting refrigerant lines.
The refrigerant system operation is controlled by the:
- A/C evaporator core orifice.
- A/C cycling switch.
- A/C compressor pressure relief valve.
- Dual function pressure switch.
The refrigerant system incorporates an A/C compressor controlled by an A/C cycling switch.
The A/C cycling switch senses A/C evaporator core pressure to control A/C compressor operation.
An A/C compressor pressure relief valve is installed in the A/C manifold and tube to protect the refrigerant system against excessively high refrigerant pressures.
An A/C evaporator core orifice is installed in the condenser to evaporator tube to meter the liquid refrigerant into the A/C evaporator core.
A/C Compressor and Clutch Assembly
NOTE:
- Internal A/C compressor components are not repaired separately. The scroll compressor is serviced only as an assembly. The A/C clutch, A/C clutch pulley and A/C clutch field coil are serviceable.
- Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator.
The Visteon Variable Scroll Compressor (SCV90) has the following characteristics:
- A variable capacity function controlled by a suction pressure sensing device.
- A fixed and orbiting scroll to provide refrigerant compression.
- A non-serviceable shaft seal.
- An A/C compressor that uses PAG oil. This oil contains special additives required for the A/C compressor.
Compressor Clutch Components:
The Visteon SCV90 compressor contains a thermal cutout switch which senses the compressor housing temperature.The switch will disengage the compressor clutch if the housing temperature exceeds 120°C (247°F)
The Visteon (SCV90) magnetic A/C clutch has the following characteristics:
- It drives the compressor shaft.
- When battery positive voltage (B+) is applied to the A/C clutch field coil, the clutch disc and hub assembly is drawn toward the A/C clutch pulley.
- The magnetic force locks the clutch disc and hub assembly and the A/C clutch pulley together as one unit, causing the compressor shaft to rotate.
- When B+ is removed from the A/C clutch field coil, springs in the clutch disc and hub assembly move the clutch disc away from the A/C clutch pulley.
A/C Compressor Pressure Relief Valve
An A/C compressor pressure relief valve is incorporated in the compressor A/C manifold and tube to:
- relieve unusually high refrigerant system discharge pressure buildups.
- prevent damage to the A/C compressor and other system components.
- avoid total refrigerant loss by closing after the excessive pressure has been relieved.
A/C Condenser Core
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator.
The A/C condenser core has the following characteristics:
- It is an aluminum fin and tube design heat exchanger located in front of the vehicle radiator.
- It cools compressed refrigerant gas by allowing air to pass over fins and tubes to extract heat and by condensing gas to liquid refrigerant as it is cooled.
Refrigerant Lines
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator.
The front condenser to evaporator tube contains high pressure liquid refrigerant. It has the following features:
- A fitting used to mount the dual function pressure switch. A long-travel Schrader-type valve stem core is installed in the fitting so that the dual function pressure switch can be removed without discharging the A/C system.
- A fitting used to mount a repairable high-pressure A/C charge port valve.
The rear condenser to evaporator tube contains the A/C evaporator core orifice. When the A/C system is in operation:
- There is high pressure liquid refrigerant upstream of the A/C evaporator core orifice.
- There is low pressure liquid refrigerant downstream of the A/C evaporator core orifice.
The A/C manifold and tube is attached to the A/C compressor with O-ring seals and has the following features:
- The upstream side contains low pressure refrigerant gas and repairable low-pressure A/C charge port valve.
- The downstream side contains high pressure refrigerant gas and an integral non-repairable muffler.
A/C Evaporator Core
NOTE:
- The evaporator core is not separately serviceable, it is serviced only with the evaporator core housing assembly.
- Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C component or damage to the suction accumulator.
The A/C evaporator core is the plate/fin type with a unique refrigerant flow path.
- A mixture of refrigerant and oil enters the bottom of the A/C evaporator core through the A/C evaporator core inlet tube and then moves out of the A/C evaporator core through the A/C evaporator core outlet tube.
- This flow pattern accelerates the flow of refrigerant and oil through the A/C evaporator core.
A/C Evaporator Core Orifice
NOTE: Install a new A/C evaporator core orifice whenever a new A/C compressor is installed.
The A/C evaporator core orifice has the following characteristics:
- it is located in the rear condenser to evaporator tube.
- it has filter screens located on the inlet and outlet ends of the tube body.
- The inlet filter screen acts as a strainer for the liquid refrigerant flowing through the A/C evaporator core orifice.
- O-ring seals on the A/C evaporator core orifice prevent the high-pressure liquid refrigerant from bypassing the A/C evaporator core orifice.
- Adjustment or repair cannot be made to the A/C evaporator core orifice assembly. It must be serviced as a unit.
Suction Accumulator
NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of system contamination from a failed A/C compressor or damage to the suction accumulator.
The suction accumulator is mounted on the A/C accumulator bracket to the right of the vehicle centerline. The inlet tube of the suction accumulator is attached to the evaporator to compressor suction line. The outlet tube attaches to the A/C manifold and tube.
After entering the inlet of the suction accumulator, heavier oil-laden refrigerant contacts an internally mounted dome (which serves as an umbrella) and drips down onto the bottom of the canister.
- A small diameter oil bleed hole, in the bottom of the vapor return tube, allows the accumulated heavier liquid refrigerant and oil mixture to re-enter the compressor suction line at a controlled rate.
- As the heavier mixture passes through the small diameter liquid bleed hole, it has a second chance to vaporize and recirculate through the A/C compressor without causing compressor damage due to slugging.
- A fine mesh screened filter fits tightly around the bottom of the vapor return tube to filter out refrigerant system contaminant particles.
- A desiccant bag is mounted inside the canister to absorb any moisture which may be in the refrigerant system.
- A fitting located on the top of the suction accumulator is used to attach the A/C cycling switch. A long-travel Schrader-type valve stem core is installed in the fitting so that the A/C cycling switch can be removed without discharging the A/C system.
A/C Cycling Switch
The A/C cycling switch is mounted on a Schrader-type valve fitting on the top of the suction accumulator.
- A valve depressor, located inside the threaded end of the A/C cycling switch, presses in on the Schrader valve stem.
- This allows the suction pressure inside the suction accumulator to control the operation of the A/C cycling switch.
- The electrical switch contacts open when the suction pressure drops. The contacts close when the suction pressure rises.
- When the A/C cycling switch contacts close, the signal to energize the A/C clutch is sent to the constant control relay module.
- When the A/C cycling switch contacts open, the A/C clutch field coil is de-energized and compressor operation stops.
- The A/C cycling switch will control the A/C evaporator core pressure at a point where the plate/fin surface temperature will be maintained slightly above freezing.
- This prevents icing of the A/C evaporator core and blockage of air flow.
- It is not necessary to discharge the refrigerant system to remove the A/C cycling switch.
Dual Function Pressure Switch
The dual function pressure switch is used to interrupt A/C compressor operation in the event of high system discharge pressures.
- The dual function pressure switch is mounted on a Schrader-type valve fitting on the high pressure side of the condenser to evaporator tube.
- A valve depressor, located inside the threaded end of the dual function pressure switch, presses on the Schrader valve stem.
- This allows the dual function pressure switch to monitor the compressor discharge pressure.
- It is not necessary to discharge the refrigerant system to remove the dual function pressure switch.
- The dual function pressure switch has two sets of contacts. One electrical contact is normally closed.
- When the compressor discharge pressure rises, the switch contacts open, disengaging the A/C compressor. When the pressure drops, the contacts close to allow operation of the A/C compressor.
The switch contains a second set of electrical contacts used for high-speed fan control.
- When the compressor discharge pressure rises, the contacts close and engage the high-speed fan control. When the pressure drops, the contacts again open and the high speed fan control is disengaged.
Spring Lock Coupling:
Spring Lock Coupling
The spring lock coupling is a refrigerant line coupling held together by a garter spring inside a circular cage.
- When the coupling is connected together, the flared end of the female fitting slips behind the garter spring inside the cage of the male fitting.
- The garter spring and cage then prevent the flared end of the female fitting from pulling out of the cage.
- Three O-ring seals are used to seal between the two halves of the A/C condenser core couplings, all other couplings have two O-ring seals.
- Use only the O-ring seals listed in the Ford Master Parts Catalog for the spring lock coupling.
- A plastic indicator ring is used on the spring lock couplings of the A/C evaporator core to indicate, during vehicle assembly, that the coupling is connected. Once the coupling is connected, the indicator ring is no longer necessary but will remain captive by the coupling near the cage opening.
- The indicator ring may also be used during service operations to indicate connection of the coupling.
- An A/C tube lock coupling clip may be used to secure the coupling but is not required.
Service Gauge Port Values:
Service Gauge Port Valves
The high-pressure service gauge port valve is located on the front condenser to evaporator tube.
The low pressure service gauge port valve is located on the A/C manifold and tube.
The fitting is an integral part of the refrigeration line or component.
- Special couplings are required for both the high side and low side service gauge ports.
- The Schrader-type valve core can be serviced if the seal leaks.
- Always install the A/C charging valve cap on the service gauge port valves after repairing the refrigerant system.