Operation CHARM: Car repair manuals for everyone.

Lifter / Lash Adjuster, Valve

Diameter (Std.) 0.6299 - 0.6294 Inch (in)
Clearance to Bore 0.000709 - 0.002717 Inch (in)
Hydraulic Leakdown Rate
Time necessary for plunger to leak down 1.6 mm of travel with 222 N force and leak down fluid in tappet.
5 - 25 Second (sec)
Collapsed Lash Adjuster Gap-Desired 00.02 - 0.03 Inch (in)