Generator On-Vehicle Tests

LOAD TEST







1. Connect the leads of Rotunda Alternator, Regulator, Battery and Starter Tester (ARBST) 010-00725 or equivalent to the vehicle, observing proper polarity.
2. Turn ARBST unit on.
3. Turn all electrical accessories off.
4. Initiate test by pushing the charging system test button on ARBST unit.
5. Start the engine and run at approximately 2000 RPM. Test will be performed automatically.
6. Return the engine to idle and second part of test will be performed automatically.
7. The ARBST unit will give peak amperage reading, peak voltage reading and diode pattern condition at conclusion of test.
8. If the peak amperage output is within 10 percent of the generator's rated output of 60 amps then the generator is functioning properly.
9. If the amperage output is below 60 amps then proceed with the next test.

NO-LOAD TEST







1. With the ignition switch in the ON position and the engine not running, verify that the voltage at the generator wiring connector terminals are as follows:
^ B-terminal = Approximately 12 volts
^ L-terminal = Approximately 1 volt
^ S-terminal = Approximately 12 volts

CAUTION: Do not ground the B-terminal.

2. Start the engine.







3. With the engine running and at normal curb idle, verify that the voltage at the generator wiring connector terminals:
4. If the voltages are as specified, check the wiring harness between the battery and the B-terminal. If the voltages are below specification, check the wiring harness. If the wiring harness is in good condition, refer to Generator Bench Tests. [1][2]Generator Bench Test