Operation CHARM: Car repair manuals for everyone.

Quick Test 4.0B - Continuous Self-Test

Using Continuous Monitor Mode (Wiggle Test)

NOTE: The Continuous Monitor Modes allow the Technician to attempt to recreate an intermittent fault.

The Manual Shift Light will illuminate when a fault is recreated.
The Self-Test Automatic Readout (STAR) Tester will indicate the fault code when a fault is recreated. The Volt Ohm Meter (VOM) will pulse (sweep) the fault code.

Engine Running
1. Hookup STAR Tester or VOM as shown in Quick Test Step 2.0.
2. START the engine.
3. DO NOT shut the engine OFF.
4. You are now in the Engine Running Continuous Monitor Mode.

NOTE: It is necessary to drive the vehicle each time the suspect sensor and/or harness is tapped, moved, or wiggled. If a fault is detected, a Service Code will be stored in memory and will be indicated as explained above.

5. Go to Quick Test Step 4.0C.