Operation CHARM: Car repair manuals for everyone.

Thermal Vacuum Valve: Description and Operation

Fig. 34 Non-linear vacuum regulator valve:





NON-LINEAR VACUUM REGULATION VALVE
The non-linear vacuum regulator (NLVR) Fig. 34, combines regulated vacuum at idle speed and carburetor ported vacuum to provide a regulated output signal to control the ignition spark advance mechanism. It is mounted in series between the vacuum source port and distributor vacuum advance unit. The NLVR has two input ports, intake manifold vacuum and carburetor ported vacuum, and one outlet port at the distributor advance unit. At curb idle, the NLVR provides regulated vacuum. Under these conditions, manifold vacuum is high and ported vacuum is either very low or non-existent. The NLVR, as determined by the calibration of the valve, provides a signal between the two vacuum levels. As engine load increases and the signal increases above the regulation point (7.5 in Hg @ 75° F ±5), the regulator valve switches to ported vacuum output.




THERMAL VACUUM SPARK CONTROL DELAY VALVE
On some models, this valve is added to the air cleaner to control vacuum between the intake manifold source and the spark CTO switch. The purpose of the valve is to allow the flow of controlled manifold vacuum when air passing through the air cleaner is below 63° F for 4-151 engines. At temperatures above this level, manifold vacuum is prevented from reaching the spark CTO until coolant temperature reaches the spark CTO switch point.