Operation CHARM: Car repair manuals for everyone.

Transmission Fluid Cooler Hose/Pipe Quick-Connect Fitting Disconnection and Connection




Transmission Fluid Cooler Hose/Pipe Quick-Connect Fitting Disconnection and Connection

Special Tools

* 7370 - Fuel Line Quick Connect Separator

* 7371 - Quick Connect Release Tool

* J 41623-B - Cooler Quick Connect Tool

* J 41769 - Fuel Line Quick Disconnect Tool

Removal Procedure - Type 1




1. Relieve the fuel system pressure. Refer to the Fuel Pressure Relief .

2. Slide the dust cover from the quick-connect fitting if a dust cover is fitted.

3. Clean any grime from the metal collar quick connect fitting.

4. Detach the metal collar quick connect fitting verifier clip (1).




5. Choose the correct special tool and install the special tool onto the male connector pipe (4).

6. Apply suitable pressure and push the special tool into the female connector (2) to release the retaining tabs.

7. Pull the female connector pipe (1) away from the male connector pipe (4).

8. Remove the special tool from the metal collar quick connect fitting.

Caution:
If necessary, remove rust or burrs from the fuel pipes with an emery cloth. Use a radial motion with the fuel pipe end in order to prevent damage to the O-ring sealing surface. Use a clean shop towel in order to wipe off the male tube ends. Inspect all the connections for dirt and burrs. Clean or replace the components and assemblies as required.

9. Clean the metal collar quick connect fittings using a clean shop towel.

10. Inspect the metal collar quick connect fittings for damage. Replace any damaged metal collar quick connect fittings.

Installation Procedure - Type 1





Warning

Always apply a few drops of clean engine oil to the male pipe ends before connecting the fuel pipe fittings. This will ensure proper reconnection and prevent a possible fuel leak. Always replace O-rings.

1. Apply a few drops of clean engine oil to the metal collar quick connect fitting.





Note: Apply suitable pressure to both ends of the metal collar quick connect fitting to make sure that the retaining tabs snap into place.

Note: Listen for an audible click to confirm the correct installation of the metal collar quick connect fitting.

2. Connect the metal collar quick connect fittings (2).

3. Install the metal collar quick connect fitting verifier clip (1).

4. Slide the dust cover into position if fitted.

Removal Procedure - Type 2




1. Remove the plastic cap from the quick connect fitting.




2. Remove the retaining ring from the quick connect fitting.




3. Remove the cooler line from the quick connect fitting.

Installation Procedure - Type 2

Note:

* Do not reuse any of the existing oil lines or oil line fittings if there is excessive corrosion.

* Do not reuse any of the existing retaining rings that were removed from the existing quick connect fittings. Install new retaining rings.

* Ensure the following procedures are performed when installing the new retaining rings onto the fittings.

1. Install a new retaining ring into the quick connect fitting using the following procedure:




2. Hook one of the open ends of the retaining ring in one of the slots on the quick connect fitting.




3. Rotate the retaining ring around the fitting until the retaining ring is positioned with all three ears through the three slots on the fitting.




4. Do not install the new retaining ring onto the fitting by pushing the retaining ring.




5. Ensure that the three retaining ring ears are seen from inside the fitting and that the retaining ring moves freely in the fitting slots.




6. Install the cooler line into the quick connect fitting.

7. Insert the cooler line end into the quick connect fitting until a click is either heard or felt.




8. Do not use the plastic cap on the cooler line in order to install the cooler line into the fitting.

9. Pull back sharply on the cooler line in order to make sure that the cooler line is fastened into the quick connect fitting.





Note: Do not manually depress the retaining clip when installing the plastic cap.

10. Position (snap) the plastic cap onto the fitting. Do not manually depress the retaining ring when installing the plastic cap onto the quick connect fitting.

11. Ensure that the plastic cap is fully seated against the fitting.




12. Ensure that no gap is present between the cap and the fitting.




13. Ensure that the yellow identification band on the tube is hidden within the quick connect fitting.




14. A hidden yellow identification band indicates proper joint seating.

15. Fill the transmission to the proper level with DEXRON(R) VI transmission fluid. Refer to Transmission Fluid Level and Condition Check Transmission Fluid Level and Condition Check.