Hydraulic Control Assembly - Antilock Brakes: Service and Repair
Brake Pressure Modulator Valve Assembly Replacement
Removal Procedure
Caution: Refer to Battery Disconnect Caution Battery Disconnect Caution in Cautions and Notices.
1. Disconnect the negative battery cable.
2. Remove the cooling surge tank. Refer to Radiator Surge Tank Replacement Service and Repair.
3. Disconnect the ABS wiring harness connector (1) from the socket on the electronic brake control module (EBCM).
4. Cover the connector and the socket with shop cloths to as protection from brake fluid.
Important: Do not allow air from the master cylinder into the hydraulic unit or the brake pipes. If air gets into the hydraulic unit, perform a bleeding procedure using a scan tool programmed for the ABS system. As long as no air enters the hydraulic unit, a simple bleeding procedure is all the system will require.
5. Remove the 6 brake pipe fitting nuts (1) from the hydraulic unit.
6. Remove the mounting bracket bolts (2) from the brake modulator assembly.
7. Remove the brake modulator assembly.
Installation Procedure
Notice: Refer to Fastener Notice Fastener Notice in Cautions and Notices.
1. Install the 6 brake pipe fitting nuts (1).
Tighten the nuts to 16 Nm (12 lb ft).
2. Install the brake modulator assembly and secure with the mounting bracket bolts (2).
Tighten the bolts to 22 Nm (16 lb ft).
3. Connect the ABS wiring harness (1).
Notice: Refer to Brake Fluid Effects on Paint and Electrical Components Notice Brake Fluid Effects on Paint and Electrical Components Notice in Cautions and Notices.
4. Inspect the fluid level of the brake master cylinder. Add new brake fluid as required.
5. Bleed the brake system. Refer to Hydraulic Brake System Bleeding Service and Repair in Hydraulic Brakes.
6. Test the brake system for leaks.
7. Install the cooling surge tank. Refer to Radiator Surge Tank Replacement Service and Repair.
8. Connect the negative battery cable.