HO2S 1
The scan tool range is
0-1275 mV. The Heated Oxygen
(HO2S) 1 parameter represents the fuel control exhaust oxygen sensor output voltage. The voltage should fluctuate constantly within a range of
10 mV (lean exhaust) and
1000 mV (rich exhaust) while operating in Closed Loop.