Fill Valve Mounting Cup Replacement
REMOVAL PROCEDURE1. Relieve the CNG fuel system pressure. Refer to Fuel Pressure Relief Procedure.
CAUTION: Refer to Battery Disconnect Caution in Service Precautions.
2. Disconnect the negative battery cable.
3. Remove the fill valve access cover.
4. Remove the fill valve.
5. Drill out the rivets from the fill valve mounting cup.
6. Carefully pry the fill valve mounting cup from the body.
7. Remove the gaskets and the adhesive from the body.
INSTALLATION PROCEDURE
1. Install a new gasket and adhesive to the body.
2. Install the fill valve mounting cup.
3. Install the rivets.
4. Install the fill valve.
5. Install the fill valve access cover.