Cooling Fan Functional Check

Diagnostic Chart:




Refer to Engine Controls Schematic Coolant Fans.

CIRCUIT DESCRIPTION
The power for the Cooling Fan Motors is supplied through the Bottom Underhood Electrical Center. The Fan Cont #1, Fan Cont #2, and Fan Cont #3 Relays are all energized when current flows from the Fan Cont #1 25A fuse and Fan Cont #2 & #3 25A fuse in the Bottom Underhood Electrical Center through the relay coils to ground through the PCM. The Low Speed Fans Control circuit is grounded for low speed fans operation. The Low Speed Fans Control circuit and the High Speed Fans Control circuits are all grounded for high speed fans operation.

During low speed fans operation the PCM supplies a ground path for the Fan Cont #1 Relay. This closes Fan Cont #1 Relay contacts, allowing current to flow from the Bottom Underhood Electrical Center through the relay contacts to the RH Cooling Fan. During low speed fans operation, the Ground path for the RH Cooling Fan is through the Fan Cont #2 Relay and the LH Cooling Fan to Ground. The result is a series circuit with both the LH Cooling Fan and the RH Cooling Fan running at low speed. During high speed fans operation the PCM supplies a ground path for the Fan Cont #1 Relay through the Low Speed Fans Control circuit. The PCM also supplies a ground path for the Fan Cont #2 Relay and the Fan Cont #3 Relay through the High Speed Fans Control circuit. This closes all three cooling fan relays. During high speed fans operation, both the LH Cooling Fan and the RH Cooling Fan are supplied current from the Bottom Underhood Electrical Center and each cooling fan has its own Ground path.

DIAGNOSTIC AIDS
If the owner complained of an overheating problem, determine if the complaint was due to an actual boil over, or the warning indicator illuminated, or the engine coolant temperature gauge indicated overheating. The gauge accuracy can also be checked by comparing the Engine Coolant Temperature (ECT) sensor reading using a scan tool and comparing its reading with the gauge reading. If the engine is actually overheating and the gauge indicated overheating, but the cooling fans are not turning ON, the ECT sensor may have shifted out of calibration and should be replaced. If the engine is overheating and the cooling fans are ON, the cooling system is suspect and should be checked.

Inspect for the following conditions:

IMPORTANT: Remove any debris from the connector surfaces before servicing a component. Inspect the connector gaskets when diagnosing or replacing a component. Ensure that the gaskets are installed correctly. The gaskets prevent contaminate intrusion.

^ Poor terminal connection - Inspect the harness connectors for backed out terminals, improper mating, broken locks, improperly formed or damaged terminals, and faulty terminal to wire connection. Use a corresponding mating terminal to test for proper tension.
^ Damaged harness - Inspect the wiring harness for damage. If the harness inspection does not reveal a problem, observe the display on the scan tool while moving connectors and wiring harnesses related to the sensor. A change in the scan tool display may indicate the location of the fault.
^ PCM and engine grounds for clean and secure connections

If the DTC is determined to be intermittent, reviewing the Failure Records can be useful in determining when the DTC was last set.

TEST DESCRIPTION
The numbers below refer to numbers on the diagnostic table:
2. The PCM will enable the engine cooling fans when certain Diagnostic Trouble Codes are set. Go to applicable DTC Table first before proceeding with this table.
3. Allow engine coolant temperature to cool below 100°C (212°F) before proceeding with diagnosis.