V5 - Conventional Mount
REMOVAL PROCEDURETOOLS REQUIRED
J 41790 Compressor Holding Fixture
1. Install the compressor into the J 41790.
2. Remove the pressure relief valve (2) from the rear head of the compressor.
INSTALLATION PROCEDURE
1. Clean the valve seat area on the rear head.
2. Lubricate the O-Ring of the new pressure relief valve and the O-Ring assembly using new 525 viscosity refrigerant oil.
NOTE: Refer to Fastener Notice in Service Precautions.
3. Install the new pressure relief valve (2).
Tighten
Tighten the valve to 9 N.m (80 lb in).
4. Evacuate and recharge the system.
5. Perform a leak test. Refer to Compressor Leak Testing (V5 - Conventional Mount).