Measuring Procedure
1. Measure the resistance between the rotor slip rings (2) with the J 39200. Standard resistance is 2.7-3.1 ohms at 20°C (68°F). If the resistance is outside of specifications, replace the rotor.
2. Measure the resistance between the rotor slip rings (2) and the rotor (1) with the J 39200. If the resistance is less than 5 ohms, replace the rotor.
3. Measure the rotor slip rings (2) with the J26900-5. The standard slip ring diameter is 14.2-14.4 mm (.559.567 in).
If the diameter is less than 12.8 mm (.504 in), or if the slip rings are rough or scored, replace the rotor.
4. Measure the resistance between all stator leads (1) with the J 39200 If the resistance is greater than 5 ohms for any measurement, replace the stator.
5. Measure the resistance between all stator leads (1) and the stator core with the J 39200. If the resistance is less than 5 ohms, replace the stator.
6. Measure the exposed brush length (2) with the J 26900-5. The standard exposed length is 10.5 mm (0.413 in). If the exposed length is less than 1.5 mm (0.059 in) replace the brush holder assembly
7. Measure the resistance between the rectifier positive terminal (4) and each rectifier terminal (3) with the J 39200. Reverse the probes and measure the resistance again. If the resistance is not less than 5 ohms in one measurement and greater than 5 ohms in the other measurement, replace the rectifier.
8. Measure the resistance between the rectifier negative terminal (3) and each rectifier terminal with the J 39200. Reverse the probes and measure the resistance again. If the resistance is not less than 5 ohms in one measurement and greater than 5 ohms in the other measurement, replace the rectifier.