Oxygen Sensor: Testing and Inspection
SCAN TOOL TESTINGThe scan tool has several positions that will indicate the state of the exhaust gases, heated oxygen sensor voltage, short term fuel trim, and long term fuel trim. Refer to Computers and Control Systems / Description and Operation.
Normal scan voltage varies between 10 mV to 1000 mV (0.01 and 1.0 volt) while in "Closed Loop." DTC 13 or DTC 63 will set if voltage remains between 0.35 and 0.55 volt, but the system will go "Open Loop." The ECM counts each time the voltage crosses the 0.45 volt reference signal. This is referred to as "cross counts."
Disconnecting the HO2S and grounding the lead from the ECM will simulate a lean HO2S condition (low voltage signal).
Applying voltage to the ECM through a digital voltmeter (J 39200) will simulate a rich exhaust condition (high voltage signal).
The ECM self-diagnostic circuit looks for trends in HO2S voltage. If a trend is detected, the Malfunction Indicator Lamp (MIL) "Service Engine Soon" comes "ON."
A rich HO2S signal trend causes the HO2S voltage to stay above 750 mV for too long. This sets DTC 45 or DTC 65.
Lean HO2S signal causes voltage to stay below 200 mV for too long. This sets DTC 44 or DTC 64. If voltage stays between 350 mV and 550 mV for too long, the ECM sets DTC 13 or DTC 63. This indicates an open heated oxygen sensor circuit.
RESPONSE TIME
Not only is it necessary for the heated oxygen sensor to produce a voltage signal for rich or lean exhaust, it is also important to respond quickly to changes. The ECM senses the response times. If the HO2S responds slowly, the customer may complain of poor fuel economy, rough idle or lack of performance. It may also set false ECM DTCs because the ECM uses heated oxygen sensor voltages for system checks.
CONTAMINANTS
Carbon
Black carbon or soot deposits result from over-rich mixtures. However, carbon does not harm a sensor. Deposits can be burned off in the engine by running it at least part throttle for two minutes.
Silica
Certain RTV silicone gasket materials give off vapors that contaminate the heated oxygen sensor. The sand like particles from the RTV silica embed in the molecules of the sensor element and plug up the surface. This results in "lazy" heated oxygen sensor response and engine control. The sensor will also have a whitish appearance.
There is also a possibility of silica contamination caused by silicone in the fuel. Careless fuel handling practices with the transport containers can result in unacceptable concentrations of silicone in the fuel at the pump.
There is also a possibility of silica contamination caused by silicon in lubricants used to install vacuum hoses on fittings.
Lead
Lead glazes sensors. It can be introduced when regular, or leaded fuel, is burned.
It is difficult to detect lead contamination by visual inspection.
Other Substances
Oil deposits will ultimately prevent sensor operation. The HO2S will have a dark brown appearance. Causes of high oil consumption should be checked. The additives in ethylene glycol can also affect sensor performance.
This produces a whitish appearance. If antifreeze enters the exhaust system, you will likely encounter other, more obvious, symptoms of cooling system trouble.
MULTIPLE FAILURES
If you encounter multiple or repeat heated oxygen sensor failures on the same vehicle, consider contamination.
Leaded fuel, silica contamination from uncured, low-grade (unapproved) RTV sealant, and high oil consumption are possible.
A problem in the heated oxygen sensor circuit or fuel system should set a DTC 13 or 63 (open circuit), DTC 44 or DTC 64 (lean indication), DTC 45 or DTC 65 (rich indication). Refer to applicable chart if any of these DTCs were stored in memory.