Table 4
1. With the Air Mix Valve Actuator Connector connected, measure the voltage to ground at terminal D (TAN/BLK). Put the Ignition Switch in RUN and set the Heater and A/C Control Assembly to AUTO (Mode). Alternately set the temperature to 15.5°C (60°F) and to 32.2°C (90°F) while monitoring the voltage at terminal D.^ Temperature Valve moves from fully open to fully closed as temperature setting is changed between 15.5°C (60°F) and 32.2°C (90°F).
^ Between 6 and 12 volts is present at terminal D in one direction of valve movement and 0 volts in the other direction.
2. Measure voltage to ground at terminal C (YEL wire) and repeat the operation described in step 1.
^ If the voltage does not change between 0 volts and 6 to 12 volts at either terminal, replace the Heater and A/C Programmer.
^ If voltage change but Temperature Valve does not move, check that valve is free to move. If valve is good mechanically, replace the Air Mix Valve Actuator:
3. Measure the voltage to ground at terminal C12 of the Heater and A/C Control Assembly. Move the Air Mix Valve by hand while observing the voltage. Voltage should vary from approximately 0 volts to approximately 5 volts as door is moved through its range.
^ If the voltage does not vary between 0 volts and 5 volts, check the DK GRN (918) wire for an open or short to ground. Replace Air Mix Valve Actuator if wire is OK.
^ If the voltage varies between 0 volts and 5 volts, replace the Heater and A/C Control Assembly