Positive Crankcase Ventilation: Service and Repair
REMOVAL PROCEDURE
1. While holding down the crankcase ventilation valve access cover (1), remove the access cover retaining bolts.
2. Remove the crankcase ventilation valve access cover (1).
3. Remove the crankcase ventilation valve (2), spring, and O-ring (3).
INSTALLATION PROCEDURE
1. Install the crankcase ventilation valve (2), spring, and new O-ring (3).
2. Install the crankcase ventilation valve access cover (1).
3. While holding down crankcase ventilation valve access cover, install the access cover retaining bolts.