Service Port HVAC: Service and Repair
Service Ports Replacement
Tools Required
* J39037 Charge Valve Octagon Socket
* J39400-A Halogen Leak Detector
Removal Procedure
1. Remove the service port cap.
2. Recover the refrigerant from the A/C system. Refer to Refrigerant Recovery and Recharging.
3. Use the J39037 to remove the service port.
Installation Procedure
1. Lightly coat the O-ring with mineral base 525 viscosity refrigerant oil.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant oil on the new O-ring to enter the refrigerant system.
Notice: Refer to Fastener Notice.
2. Install the service port.
Tighten the service port to 11 N.m (98 lb in).
3. Evacuate and recharge the A/C system. Refer to Refrigerant Recovery and Recharging.
4. Leak test the fittings of the component using J39400-A.
5. Install the service port cap.
Tighten the cap 1/4-1/2 turn after the seal washer contacts to access fitting.